Anticorrosion lab evaluation
HTHP Test in Autoclave Environment
Criterion: NACE TM 0185-2000
Principle: put prepared coating coupons in a autoclave, which contains certain solution, and set the autoclave at certain pressure and temperature for a period of time and the take out and evaluate the coupons by Criterion.
Sample: Window cutting sample for commercial check and coating coupon for coating material check according to GB/T 1727
Environment: Luojiazai gas field, Tarim fields, Pinghu gas field
Inspection: Sour gas field material corrosion evaluation center of Sichuan bureau, CNPC
|